AJP - Regu Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Regul Integr Comp Physiol 266: R1786-R1791, 1994;
0363-6119/94 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Chou, H. F.
Right arrow Articles by Ipp, E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Chou, H. F.
Right arrow Articles by Ipp, E.

AJP - Regulatory, Integrative and Comparative Physiology, Vol 266, Issue 6 1786-R1791, Copyright © 1994 by American Physiological Society


ARTICLES

Evidence for pancreatic pacemaker for insulin oscillations in low-frequency range

H. F. Chou, N. Berman and E. Ipp
Department of Medicine, Harbor-University of California Los Angeles Medical Center, Torrance 90502.

Circulating insulin concentrations oscillate in regular fashion, with periods that fall into a high-frequency (period of 5-17 min) or low-frequency (period of 50-150 min) range. Only the high-frequency oscillations have so far been reported in vitro, suggesting that these derive from a primary pancreatic source. This study tested whether the low-frequency insulin oscillations could also be identified in vitro. Rat islets of Langerhans were perifused for 20 h using RPMI medium with 5.5 mM glucose. Perifusate fractions were collected at 9.9-min intervals. Mean insulin concentrations at the outset were 21.4 +/- 2.9 microU/ml, increased to 32.5 +/- 4.6 (P < 0.05) between 13 and 17 h after the start of perifusion, and then either leveled off or decreased to baseline. Superimposed on this general trend, we found sustained insulin oscillations with a period of 50-100 min. The mean amplitude was 14.2 +/- 4.2 microU/ml, and the amplitude/mean ratio was 64.6 +/- 12%. Spectral analysis revealed significant peaks at periods that were close to either 50 or 100 min and a smaller peak at 24-37 min. These data, using in vitro methodology and constant glucose concentrations, indicate the presence of sustained, spontaneous, low-frequency, ultradian insulin oscillations in the pancreatic islets. This provides evidence for a pancreatic component that may participate in the previously described in vivo ultradian insulin oscillations. This finding may also provide a mechanism for the apparent escape from glucose entrainment of serum insulin oscillations in non-insulin-dependent diabetes mellitus.


This article has been cited by other articles:


Home page
DiabetesHome page
C. Simon and G. Brandenberger
Ultradian Oscillations of Insulin Secretion in Humans
Diabetes, February 1, 2002; 51(90001): S258 - 261.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online