AJP - Regu AJP: Lung Cellular and Molecular Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Regul Integr Comp Physiol 260: R668-R671, 1991;
0363-6119/91 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Drake, R. E.
Right arrow Articles by Gabel, J. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Drake, R. E.
Right arrow Articles by Gabel, J. C.

AJP - Regulatory, Integrative and Comparative Physiology, Vol 260, Issue 4 668-R671, Copyright © 1991 by American Physiological Society


ARTICLES

Effect of outflow pressure on intestinal lymph flow in unanesthetized sheep

R. E. Drake and J. C. Gabel
Center for Microvascular and Lymphatic Studies, University of Texas Medical School, Houston 77030.

Lymphatic vessels are important in removing excess fluid from the intestines and preventing intestinal edema. In this study we used the relationship between intestinal lymph flow rate (QL) and lymphatic outflow pressure (PO) to analyze the flow from intestinal lymphatics in unanesthetized sheep. We cannulated intestinal lymphatic vessels in six anesthetized sheep. One to 3 days after the surgery, we measured QL as we increased PO in steps. We found no QL decrease until PO greater than 15 cmH2O, but QL decreased significantly for PO greater than 15 cmH2O and was decreased to zero at PO = 34 +/- 13 (SD) cmH2O. In three experiments, we used the pressure pulses generated by the active lymphatic pump to estimate the pump stroke volume and frequency. These data indicate that increases in lymphatic pumping prevented a QL decreased for PO less than 15 cmH2O and the QL decrease for PO greater than 15 cmH2O was associated with lymphatic pump failure. When we increased portal venous pressure from baseline (10.1 +/- 4.1 cmH2O) to 24.3 +/- 6.2 cmH2O, lymph flow increased, but it was much more sensitive to outflow pressure. These results are important because they indicate that the ability of the lymphatics to remove fluid from edematous intestines may be compromised by small increases in lymphatic outflow pressure.


This article has been cited by other articles:


Home page
Am. J. Physiol. Regul. Integr. Comp. Physiol.Home page
C. M. Quick, A. M. Venugopal, A. A. Gashev, D. C. Zawieja, and R. H. Stewart
Intrinsic pump-conduit behavior of lymphangions
Am J Physiol Regulatory Integrative Comp Physiol, April 1, 2007; 292(4): R1510 - R1518.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
J. W. Klaesner, N. A. Pou, R. E. Parker, C. Finney, and R. J. Roselli
Optical measurement of isolated canine lung filtration coefficients after alloxan infusion
J Appl Physiol, April 1, 1998; 84(4): 1381 - 1387.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Regul. Integr. Comp. Physiol.Home page
R. E. Drake, R. A. Teague, and J. C. Gabel
Effect of sheep plasma and lymph on fibroblast proliferation
Am J Physiol Regulatory Integrative Comp Physiol, February 1, 1998; 274(2): R561 - R563.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online