AJP - Regu Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Regul Integr Comp Physiol 259: R313-R316, 1990;
0363-6119/90 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Andersen, S. E.
Right arrow Articles by Bie, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Andersen, S. E.
Right arrow Articles by Bie, P.

AJP - Regulatory, Integrative and Comparative Physiology, Vol 259, Issue 2 313-R316, Copyright © 1990 by American Physiological Society


ARTICLES

Continuous servo-controlled replacement of urinary sodium loss in conscious dogs

S. E. Andersen and P. Bie
Department of Medical Physiology C, Panum Institute, University of Copenhagen, Denmark.

A method for continuous servo-controlled infusion of sodium chloride to dogs is reported. The servo system consists of a sodium-sensitive electrode, a modified commercial flowmeter, a thermistor, a control unit, and a pump. Based on analog inputs from electrode, flowmeter, and thermistor, the control unit generates appropriate numbers of voltage steps, which drive the pump infusing a concentrated solution of sodium chloride. Inputs from the thermistor are necessary to correct for the influence of fluctuations in urine temperature. The sodium servo system has been tested together with a weight servo mechanism in conscious water-diuretic dogs. Furosemide (1 microgram.kg-1.min-1) was infused to change the rate of sodium excretion by a factor of 17 from 3 +/- 1 to 50 +/- 15 mumols/min. Within this range, the apparatus replaced the sodium losses with great accuracy. From seven experiments the average system response in micromoles per minute (NaIn) measured in 10-min periods against mean renal excretion of sodium (NaEx) was NaIn = 0.98.NaEx - 1.37. The servo system provides a tool for accurate maintenance of body sodium irrespective of large changes in the rate of sodium excretion.


This article has been cited by other articles:


Home page
Am. J. Physiol. Renal Physiol.Home page
T. E. N. Jonassen, L. Brond, M. Torp, M. Grabe, S. Nielsen, O. Skott, N. Marcussen, and S. Christensen